If you have vinyl aluminum or steel siding it s probably easier to remove it from the entire garage wall and reinstall it after the addition is built.
Garage slab siding starter course 6 clearance.
Wall sheathing and 2 in.
Flashing must be located beneath the first course of masonry above finished ground level above the foundation wall or slab and at other points of support including structural floors shelf angles and lintels when masonry veneers are designed per section r703 7.
This requirement is not just to prevent damage to the siding it serves a couple of other functions as well.
Epoxy in some anchor bolts to keep the garage in place.
Pry off the siding and remove the wall photo 2.
I would put an 6 or 8 thick block 8 high on the existing slab.
Amerimax 3 in x 120 in unpainted aluminum starter strip metal siding trim.
We cut the wood siding 2 1 2 in.
This article will examine just that question of the recommended distance from ground and siding your clearance is vitally important for the siding s long term protection and safeguard.
A 6 mil polyethylene or approved vapor retarder with joints lapped minimum 6 inches shall be placed between a concrete slab on grade and the base course or subgrade.
Installing vinyl siding to an unlevel garage in this application throw the metal starter strip away after papering the wall with a two layers of 30 minute building paper install a j trim parallel to the bottom of the wood frame wall but overlapping its bottom 1 2 to 3 4 inch.
Having your siding too close to the ground is just asking.
The 8 height helps to get the garage up and above the present exterior grade and will be enough for the future.
Maintaining proper clearances reduces access to wood structures behind the siding by wood destroying insects or damage from water that might.
For pricing and availability.
Since it is a rehab and then tie down a sill and put the garage back on it.
I have had better luck with white silicon than clear.
As shown in the diagram a wooden spacer can be used to provide the proper angle for the first strip.
Do not use a j channel.
Most manufacturers produce a starter strip that secures the bottom course of siding to the sheathing and holds it at the proper angle.
Ever wonder if siding is too close to the ground.
Beyond the width of the addition to allow for 1 2 in.
Siding materials need proper clearances between finish grade and the siding regardless the type of siding.
Foundation plates or sills shall be bolted or anchored to the foundation or foundation wall per the follow ing crc r403 1 6 and crc r602.
When building your new home have you ever wondered how close your siding needs to be from the ground.
The clear seems to debond from concrete after awhile.
Anchor bolts and sills.